• Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect
  • Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect
  • Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect
  • Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect
  • Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect

Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect

Type: Hall Type
Output Signal Type: Analog Output
Production Process: Integration
Material: Plastic
Accuracy Grade: 1.0G
Application: Motor Controller
Samples:
US$ 8/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Jiangsu, China
to see all verified strength labels (30)

Basic Info.

Model NO.
TKC-EKA565
IP Rating
IP56
Certification
RoHS;CE;ISO
Customized
Customized
Transport Package
Carton
Specification
72g
Trademark
TOKEN
Origin
China
HS Code
8504909090
Production Capacity
200000/Month

Product Description

Product description:

Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect

TKC-EKA565 series current sensor is a open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

  
 Electrical data(Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF)
 
Type

Parameter

TKC50 EKA565

TKC100 EKA565

TKC200 EKA565

TKC300 EKA565

TKC500 EKA565

Unit
(Ipn) Rated current(Ipn) ±50 ±100 ±200 ±300 ±500 A
(Ip) Measuring range(Ip) ±150 ±300 ±600 ±900 ±1000 A
Rated output @Ip=±Ipn   ±0.625±5%     V
Supply voltage +5±5% V

Power Consumption
≤20 mA
Reference voltage +2.5±0.4% V
Zero voltage @Ip=0   +2.5±0.5%     V
Offset voltage @Ip=0   ±20     mV
Magnetic offset @Ip=±Ipn-0   ±20     mV
Offset drift @ -40~+85ºC   ≤±2     mV/ºC
output drift @ -40~+85ºC   ≤±2     mV/ºC
Linearity @Ip=0-±Ipn   ≤1     %FS
Response time @50A/μS, 10%-90%   ≤5     μS

Galvanic isolation
@ 50HZ,AC,1min   2.5     KV

Bandwidth
@DC,(-3dB)                                 25     KHz

Isolation resistance
@ DC 500V   1000    

Major electric parameters: 
Hole size: 20mm
Power supply: DC +5V
connector type:15EDGVC-3.5-04P
Input signal: 50-500A optional (let us know which one do you want)
Accuracy: 1.0% FS
Output: 2.5±0.625V

Details
Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect





Company information

Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect
Application

Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect
Why choose us?

Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect


Packaging and Shipping

Detachable Current Sensor Tkc-Eka565 Series Accuracy 1% AC DC and Pulse Current Detect




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
99
Year of Establishment
2002-05-23