Type: | Hall Type |
---|---|
Output Signal Type: | Analog Output |
Production Process: | Integration |
Material: | Plastic |
Accuracy Grade: | 1.0G |
Application: | Industrial Control Equipment |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Electrical data(Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF) |
Type Parameter |
TKC 100F51 |
TKC 300F51 |
TKC 500F51 |
TKC 600F51 |
TKC 800F51 |
TKC 1000F51 |
TKC 2000F51 |
Unit |
|||
(Ipn) Rated input (Ipn) | ±100 |
±300 |
±500 |
±600 |
±800 |
±1000 |
±2000 |
A |
|||
(Ip) Measure range(Ip) | ±200 |
±600 |
±1000 |
±1200 |
±1600 |
±2000 |
±3000 |
A |
|||
Rated output | @Ip=±Ipn |
±1±1% |
V |
||||||||
Supply voltage | +5±5% |
V |
|||||||||
Power Consumption |
+18 |
mA |
|||||||||
Zero voltage | @Ip=0 |
2.5±0.5% |
V |
||||||||
Offset voltage | @Ip=0 |
≤±15 |
mV |
||||||||
Magnetic offset | @Ip=±Ipn |
≤±20 |
mV |
||||||||
Offset drift | @ -40~+85ºC |
≤±0.5(Typ),≤±0.75(Max) |
mV/ºC |
||||||||
output drift | @ -40~+85ºC |
≤±0.5(Typ),≤±0.75(Max) |
mV/ºC |
||||||||
Linearity | @Ip=0-±Ipn |
≤1 |
%FS |
||||||||
Response time | @50A/μ S, 10%-90% | ≤5 |
μ S | ||||||||
Bandwidth |
@DC,(-3dB) 25 | KHz | |||||||||
Galvanic isolation |
@ 50HZ,AC,1min |
5.0 |
KV |