Customization: | Available |
---|---|
Type: | Hall Type |
Output Signal Type: | Analog Output |
Still deciding? Get samples of US$ 14/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electrical data(Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF) |
Type Parameter |
TKC 100FA |
TKC 200FA |
TKC 500FA |
TKC 800FA |
TKC 1000FA |
TKC 1200FA |
TKC 1500FA |
TKC 2000FA |
Unit |
(Ipn) Rated input (Ipn) |
100 | 300 | 500 | 800 | 1000 | 1200 | 1500 | 2000 | A |
(Ip) Measure range(Ip) |
±300 | ±600 | ±1000 | ±1600 | ±2000 | ±2400 | ±3000 | ±3000 | A |
Rated output |
@Ip=±Ipn ±4±1% | V | |||||||
Supply voltage |
±15±5% | V | |||||||
Power Consumption |
+18,-10 | mA | |||||||
Offset voltage |
@Ip=0 ≤15 | mV | |||||||
Magnetic offset |
@Ip=±Ipn ≤±30 | mV | |||||||
Offset drift |
@ -40~+85ºC ≤±0.5(Typ),≤±0.75(Max) | mV/ºC | |||||||
Output drift |
@ -40~+85ºC ≤±0.5(Typ),≤±0.75(Max) | mV/ºC | |||||||
Linearity |
@Ip=0-±Ipn ≤1 | %FS | |||||||
Response time |
@50A/μS, 10%-90% ≤5 | μS | |||||||
Bandwidth |
@ -3dB DC-25 | KHz | |||||||
Galvanic isolation |
@ 50HZ,AC,1min 5.0 | KV |