Type: | Hall Type |
---|---|
Output Signal Type: | Analog Output |
Production Process: | Integration |
Material: | Plastic |
Accuracy Grade: | 1.0G |
Application: | Converter |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Electrical data(Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF) |
Type Parameter |
TKC 1000HB |
TKC 2000HB |
TKC 3000HB |
TKC 5000HB |
TKC 8000HB |
TKC 15000HB |
TKC 20000HB |
Unit |
(Ipn) Rated current(Ipn) |
±1000 | ±2000 | ±3000 | ±5000 | ±8000 | ±10000 | ±20000 | A |
(Ip) Measuring range(Ip) |
±2000 | ±6000 | ±9000 | ±10000 | ±16000 | ±20000 | ±30000 | A |
Rated output |
@Ip=±Ipn ±4±1% | V | ||||||
Supply voltage |
±15 ±5% | V | ||||||
Power Consumption |
+45,-15 | mA | ||||||
Offset voltage |
@Ip=0 ±20 | mV | ||||||
Magnetic offset |
@Ip=±Ipn-0 ±30 | mV | ||||||
Offset drift |
@ -40~+85ºC ≤±0.5 | mV/ºC | ||||||
output drift |
@ -40~+85ºC ≤±0.5 | mV/ºC | ||||||
Linearity |
@Ip=0-±Ipn ≤1 | %FS | ||||||
Response time |
@50A/μS, 10%-90% ≤10 | μS | ||||||
Bandwidth |
@DC,(-3dB) 25 | KHz | ||||||
Galvanic isolation |
@ 50HZ,AC,1min 6 | KV |
Suppliers with verified business licenses