Type: | Hall Type |
---|---|
Output Signal Type: | Analog Output |
Production Process: | Integration |
Material: | Plastic |
Accuracy Grade: | 1.0G |
Application: | Converter |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Electrical data(Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF) |
Type Parameter |
TKC50 BS1 |
TKC75 BS1 |
TKC100 BS1 |
TKC200 BS1 |
TKC300 BS1 |
TKC400 BS1 |
TKC500 BS1 |
TKC600 BS1 |
Unit |
(Ipn) Rated input (Ipn) |
±50 | ±75 | ±100 | ±200 | ±300 | ±400 | ±500 | ±600 | A |
(Ip) Measure range(Ip) |
±150 | ±225 | ±300 | ±600 | ±900 | ±900 | ±900 | ±900 | A |
Rated output |
@Ip=±Ipn ±4±1% | V | |||||||
Supply voltage |
±15 ±5% | V | |||||||
Power Consumption |
+15,-10 | mA | |||||||
Offset voltage |
±25 | mV | |||||||
Magnetic offset |
±30 | ±25 | mV | ||||||
Offset drift |
≤±1.5 | ≤±1.0(Typ),≤±1.5(Max) | mV/ºC | ||||||
output drift |
≤±1.5 | ≤±1.0(Typ),≤±1.5(Max) | mV/ºC | ||||||
Linearity |
@Ip=0-±Ipn ≤1 | %FS | |||||||
Response time |
@50A/μS, 10%-90% ≤3 | μS | |||||||
Bandwidth |
@DC,(-3dB) 25 | KHz | |||||||
Galvanic isolation |
@ 50HZ,AC,1min 2.5 | KV |