Type: | Hall Type |
---|---|
Output Signal Type: | Analog Output |
Production Process: | Integration |
Material: | Plastic |
Accuracy Grade: | 1.0G |
Application: | Switching Power Supply |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Electrical data(Ta=-25ºC±5ºC,RL=2KΩ,CL=10000PF) |
Type Parameter |
TKC50 TF512 | TKC100 TF512 | TKC200 TF512 | TKC300 TF512 | TKC400 TF512 | TKC800 TF512 | Unit | |
(Ipn) Rated input | ±50 |
±100 |
±200 |
±300 |
±400 |
±800 |
A |
|
Measure range | ±75 |
±150 |
±300 |
±450 |
±600 |
±1200 |
A |
|
Rated output | @Ip=±Ipn |
±1.25±1% |
V |
|||||
Zero voltage | @Ip=0 |
1/2 VCC±1% |
V |
|||||
Reference voltage | 2.5±0.5% |
V |
||||||
Supply voltage | +5±5% |
V |
||||||
Power Consumption |
≤15 |
mA |
||||||
Zero offset voltage |
≤±20 |
mV |
||||||
Magnetic offset | ±15 |
±10 |
mV |
|||||
Offset drift | ≤±1.0 |
≤±0.5 |
mV/ºC |
|||||
output drift | ≤±1.0 |
≤±0.5 |
mV/ºC |
|||||
Linearity | @Ip=0-±Ipn |
≤1 |
%FS |
|||||
Response time | @50A/μ S, 10%-90% | ≤3 |
μ S | |||||
Bandwidth |
@DC,(-3dB) 20 | KHz | ||||||
Galvanic isolation |
@ 50HZ,AC,1min |
2.5 |
KV |
Suppliers with verified business licenses